Control Panel
Additional resources
Close Early Begin, page 211
Open Window Stop, page 211
11.1.6

Open Window Stop

Default: Disable
Selections: Disable, HH:MM (hours and minutes)
Enter the time that you want the control panel to end the opening window. The window stops
at the end of the minute.
00:00 is Midnight 23:59 is 11:59 P.M. Make entries using a 24-hour clock (for example, 7:00
AM is entered as 07:00, 2:45 PM is entered as 14:45).
This parameter is one of three required to create an opening window. To program an opening
window, Close Early Begin, page 211 and Open Window Start, page 210 must also be
programmed.
If the area is not disarmed by the time the Open Window Stop, page 211 time expires, the
control panel generates a FAIL TO OPEN report if enabled in Fail to Open, page 104.
Opening reports generated between the Open Window Start time and Open Window Stop
time can be suppressed by setting Disable O/C in Window, page 103 to Yes. Refer to Open
Early Begin for other report feature explanations.
Do not use a time of 23:59 as a window stop time unless another window begins on the next
day at 00:00.
The control panel does not send FAIL TO OPEN reports for windows that stop at 23:59.
RPS Menu Location
Schedules > Open/Close Windows > Open Window Stop
11.1.7

Close Early Begin

Default: Disable
Selections: Disable, HH:MM (hours and minutes) 00:00 to 23:59
This parameter is one of three required to create a closing window. To finish programming a
closing window, Close Window Start, page 212 and Close Window Stop, page 212 must be
programmed.
The time entered in this parameter is the earliest time the user can close an area before the
Close Window Start time. If opening and closing reports are enabled, arming the area between
midnight and the time entered in this parameter generates a closing report.
If Disable O/C in Window, page 103 is set to Yes and the area is armed between the Close Early
Begin time and the Close Window Start time, the closing event is sent with an Early to Close
modifier. If the Close Early Begin time is the same as the Close Window Start time, no closing
event is sent.
If Disable O/C in Window is set to No and the area is armed at any time, a closing event is sent
without the Early to Close or Late to Close modifiers.
Arming the area between the Close Window Start and Close Window Stop times creates a
local event in the control panel event log, but does not send the closing report to the central
station.
Arming the area after the Close Window Stop time and before the next window's Close Early
Begin time (or midnight, whichever is earlier) generates a closing event with a Late to Close
modifier.
When configuring multiple windows to operate on the same day, ensure that they are added to
the system in chronological order. For example, if three windows are programmed to execute
on Tuesday, Window 1 (W1) must occur before Window 2 (W2), and Window 2 must occur
before Window 3 (W3).