Personal Notification Reports; Personal Notification Routing Attempts; Email Server Configuration - Bosch B9512G Program Entry Manual

Security system
Hide thumbs Also See for B9512G:
Table of Contents

Advertisement

Control Panel
3.17

Personal Notification Reports

IMPORTANT CELLULAR SERVICE INFORMATION
Refer to Configuring for Cellular Service, page 280 for important information regarding how to
set up your control panel to ensure proper cellular communication with the central station
receiver.
Default:
Selections: 1-32
This parameter can be set to send personal notifications to a cellular device or email address.
The control panel sends personal notifications to a cellular device when the programmed
destination is a valid cellular telephone number containing only numbers 0-9. Properly
interspersed hyphens are allowed, but not required.
The control panel sends personal notifications to email accounts when the programmed
destination is a valid email address. An email address is considered valid if it is copied
verbatim from an internet email provider.
Notice!
If the destination is neither a valid phone or valid email, no message will be sent, and an SMS
send error will be logged.
Notice!
You are not required to set the Primary or Backup Destination Device parameters to Cellular
IP for Personal Notification by SMS to work.
RPS Menu Location
Panel Wide Parameters > Personal Notification > Personal Notifications Reports > Personal
Notification 1-4
3.18

Personal Notification Routing Attempts

Default: 3
Selections: 1-6
This parameter sets the maximum number of attempts the control panel makes to send a
personal notification.
RPS Menu Location
Panel Wide Parameters > Personal Notification > Personal Notification Routing Attempts
3.19

Email Server Configuration

You can program the control panels to send personal notifications to one or more email
addresses (up to 16 destinations).
When an event occurs, the control panel transmits a report across an IP network to an email
server. The SMTP (Simple Mail Transfer Protocol) email server translates the incoming data
into text and then pushes it out to the destinations you programmed. This is a one-way
communication from the control panel to the user.
Bosch Security Systems, Inc.
Route Groups 1-3     0:Disabled
Route Group 4         Personal notification # 1-8
Program Entry Guide
Panel Wide Parameters | en
2017.03 | 09 | F.01U.303.998
87

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B8512gB8512g-eB9512g-e