When Port Number/IP Address pairs have duplicate values in a control panel, RPS shows a
warning message and asks if you wish to continue. If you click No, RPS forces you to enter
unique values for the Port Number and IP Address fields. If you click Yes, RPS allows you to
enter duplicate values.
RPS Menu Location
Panel Wide Parameters > Enhanced Communications > Network Address (Destinations 1-4)
3.11.3

Port Number

Default: 7700
Selections: 1 to 65,535
This parameter assigns a unique port number for each destination used to communicate with
the central station over a network.
When upgrading a non-control panel account to a control panel account, RPS forces the
default to 7700.
Whenever the central station requests a change to the Network Address, page 62 or Port
Number, page 63 configured in the control panel, the central station receiver might
resynchronize the control panel's anti-replay/anti-substitution static key.
When Port Number/IP Address pairs have duplicate values in a control panel, RPS shows a
warning message and asks if you wish to continue. If you click No, RPS forces you to enter
unique values for the Port Number and IP Address fields. If you click Yes, RPS allows you to
enter duplicate values.
RPS Menu Location
Panel Wide Parameters > Enhanced Communications > Port Number (Destination 1 to 4)
3.11.4

Receiver Supervision Time

Default: 4 Hours - Medium Security
Selections:
With the exception of the Custom selection, the Receiver Supervision Time selection
automatically sets the Poll Rate (sec.), page 64, ACK Wait Time (sec.), page 66, and Retry
Count, page 66 parameters. These parameters can only be edited when the Receiver
Supervision Time parameter is set to Custom.
The first time Custom is selected, the default value for the Poll Rate, ACK Wait and Retry
Count parameters is zero. Once these parameters are changed from the default, RPS retains
the values even if the Receiver Supervision Time parameter is changed from the Custom
selection. Each time Custom is reselected the Poll Rate, ACK Wait and Retry Count parameters
are set to the saved values.
Bosch Security Systems, Inc.
200 Seconds - UL1610
300 Seconds - NFPA 72 2010
1 Hour - NFPA 72 2013
4 Hours - Medium Security
24 Hours - Daily
25 - Hours
90 Seconds - High Security
No Polling
95-195, 205-1275 Seconds - selections available in 5 second intervals
2, 3, 5-23, 26-255 Hours
Custom
Program Entry Guide
Panel Wide Parameters | en
2017.03 | 09 | F.01U.303.998
63