150 en | User Configuration
9.3.3
Part On, Instant
Default: P
Selections: - , E, P
–
–
–
This function turns areas part on with no entry/exit delays in the area where the keypad is
assigned. This causes perimeter and interior delay points to act as instant points.
Notice!
To comply with SIA CP-01 False Alarm Reduction, set this parameter to Disabled (-). Refer to
SIA CP-01 Verification for more information.
RPS Menu Location
User Configuration > User Keypad Functions > Part On Instant.
9.3.4
Part On, Delay
Default: P
Selections: - , E, P
–
–
–
This function turns areas part on with entry/exit delays in the area where the keypad is
assigned.
Entry and exit delays are provided with this arming function. This will not cause a Part On
instant point to act as a delay point.
RPS Menu Location
User Configuration > User Keypad Functions > Part On Delay.
9.3.5
Watch Mode
Default: E
Selections: - , E, P
–
–
–
This function turns watch mode on and off.
This function provides keypad audible/visual and optional output activation when a point
configured for Watch Mode is activated. (Refer to Watch Mode in the Area Wide Outputs
section).
RPS Menu Location
User Configuration > User Keypad Functions > Watch Mode
9.3.6
View Area Status
Default: P
Selections: - , E, P
–
–
–
This function allows the user to view the armed status of all areas within the scope of the
keypad.
2017.03 | 09 | F.01U.303.998
Disable (-) - Disable this function panel wide regardless of the user's authority level.
Enable (E) - Enable this function panel wide without requiring a passcode.
Passcode (P) - Require a passcode to enable this function panel wide.
Disable (-) - Disable this function panel wide regardless of the user's authority level.
Enable (E) - Enable this function panel wide without requiring a passcode.
Passcode (P) - Require a passcode to enable this function panel wide.
Disable (-) - Disable this function panel wide regardless of the user's authority level.
Enable (E) - Enable this function panel wide without requiring a passcode.
Passcode (P) - Require a passcode to enable this function panel wide.
Disable (-) - Disable this function panel wide regardless of the user's authority level.
Enable (E) - Enable this function panel wide without requiring a passcode.
Passcode (P) - Require a passcode to enable this function panel wide.
Program Entry Guide
Control Panel
Bosch Security Systems, Inc.