en | Compliance Settings
2
Compliance Settings
2.1
SIA CP-01 Verification
Default: No
Selections:
–
–
This parameter specifies whether or not this control panel requires SIA CP-01 False Alarm
Reduction compliance.
If RPS receives programming data from the control panel that is not SIA CP-01-compliant, the
SIA CP-01 Compliance window opens. Parameters that are out of compliance are listed.
Making the parameters SIA CP-01 compliant:
1.
2.
If a control panel account contains parameters that do not comply with SIA CP-01, and you
retrieve that data using the Unattended Mode feature, RPS stores the non-compliant data
regardless of the SIA CP-01 parameter's setting.
2017.03 | 09 | F.01U.303.998
Yes. Check the following parameters for SIA CP-01 compliance:
–
Duress Type, page 74
–
Alarm Bell, page 133
–
Exit Delay Time, page 94
–
Burg Time, page 100
–
Exit Delay Warning, page 107
–
Entry Delay Warning, page 107
–
Entry Delay, page 190
–
Passcode Length, page 79
–
Remote Warning, page 81
–
Swinger Bypass Count, page 80
–
Cancel Reports, page 75
–
Two Man Rule?, page 98 ?
–
Early Ambush?, page 99?
–
All On, Instant, page 159
–
Part On, Instant, page 160
–
Passcode Enter Function, page 113
No. Do not check parameters for SIA CP-01 compliance.
Enter a value under the Desired Value column that is between the compliant SIA minimum
and maximum values.
Select one of the following options:
–
Set the SIA CP-01 Verification to No and store the existing data in this account.
–
Leave the SIA CP-01 Verification Parameter to Yes and store the data in the Desired
Value field in this account.
Program Entry Guide
Control Panel