en | Compliance Settings
2

Compliance Settings

2.1

SIA CP-01 Verification

Default: No
Selections:
This parameter specifies whether or not this control panel requires SIA CP-01 False Alarm
Reduction compliance.
If RPS receives programming data from the control panel that is not SIA CP-01-compliant, the
SIA CP-01 Compliance window opens. Parameters that are out of compliance are listed.
Making the parameters SIA CP-01 compliant:
1.
2.
If a control panel account contains parameters that do not comply with SIA CP-01, and you
retrieve that data using the Unattended Mode feature, RPS stores the non-compliant data
regardless of the SIA CP-01 parameter's setting.
2017.03 | 09 | F.01U.303.998
Yes. Check the following parameters for SIA CP-01 compliance:
Duress Type, page 74
Alarm Bell, page 133
Exit Delay Time, page 94
Burg Time, page 100
Exit Delay Warning, page 107
Entry Delay Warning, page 107
Entry Delay, page 190
Passcode Length, page 79
Remote Warning, page 81
Swinger Bypass Count, page 80
Cancel Reports, page 75
Two Man Rule?, page 98 ?
Early Ambush?, page 99?
All On, Instant, page 159
Part On, Instant, page 160
Passcode Enter Function, page 113
No. Do not check parameters for SIA CP-01 compliance.
Enter a value under the Desired Value column that is between the compliant SIA minimum
and maximum values.
Select one of the following options:
Set the SIA CP-01 Verification to No and store the existing data in this account.
Leave the SIA CP-01 Verification Parameter to Yes and store the data in the Desired
Value field in this account.