137 Tamper; Panic; Zone Type; 24 Hr Safe - Bosch DS7200V2-UK Installer's Manual

Table of Contents

Advertisement

Event as shown
Event #
SIA Report
in Panel Log
94
Open,RPS,Alarm
Disarm from
Alarm
95
Open,Usr,Alarm
Disarm from
Alarm
96
Open,KS,Alarm
Disarm from
Alarm
97
Reserved
98
Params Changed
Parameter
Changed
99
Phone Line Fail
Phone Line
Trouble
100
Phone Line Rstl
Phone Line
Restoral
101
Bad Call to RPS
Remote
Programmer
Call Failed
102
RPS Access Fail
Remote
Program
Fail
103
RPS Access OK
Valid
Remote
Access
104
Re-Boot,Panel
Power Up
105
Re-Boot,DBus
Power Up
106
Output Reset,Usr
Relay Open id {user} RO {output #} 320 Sounder/Relay Output Reset by User
107
Output Reset,Tmr
Relay Open id {252} RO {output #}
108
Output Reset,
Relay Open id {254} RO {output #}
RPS
109
Output Set,Usr
Relay Close id {user} RC {output #} 320 Sounder/Relay Output Set by User
110
Output Set,Tmr
Relay Close id {252} RC {output #}
111
Output Set,RPS
Relay Close id {254} RC {output #}
112
Rstrl,Tamper
Tamper
Restoral
113
Rstrl,Emergency
Emergency
Restoral
114
Rstrl,Panic

Panic

Restoral
115
Rstrl,Invisible
Holdup
Restoral
116
Rstrl,24-hr Burg
Burglary
Restoral
117
Rstrl,Cntrl,Dly
Burglary
Restoral
118
Rstrl,Cntrl
Burglary
Restoral
119
Rcvr Jam
RF
Interference
120
Rcvr Jam Rstl
RF
Interference
Restoral
DS7200V2-UK Installer's Guide
SIA Report Data
Contact ID Report
ri {area} OR {254}
400 Open/Close
ri {area} OR {user}
401 O/C by User
ri {area} OR {255}
409 Keyswitch O/C Opening after Alarm event
YG
306 Panel
Programming
Changed
LT {phone line}
351 Telco 1 fault
LR {phone line}
351 Telco 1 fault
RA
413 Unsuccessful
access
RU
413 Unsuccessful
access
RS
412 Successful
Download/Access
RR
305 System reset
pi {SDI address} RR
339 Exp. Module
Reset
320 Sounder/Relay Output Reset by Sked
320 Sounder/Relay Output Reset by RPS
320 Sounder/Relay Output Set by Sked (Timer)
320 Sounder/Relay Output Set by RPS
ri {area} TR {loop}

137 Tamper

ri {area} QR {loop}
101 Personal
Emergency
ri {area} PR {loop}
120 Panic
ri {area} HR {loop}
120 Panic
ri {area} BR {loop}
133 24hr (Safe)
ri {area} BR {loop}

134 Entry/Exit

ri {area} BR {loop}

130 Burglary

XQ {RF device #}
344 RF Receiver
Jam Detect
XH {RF device #}
344 RF Receiver
Jam Detect
Restoral
Table 47: Control Panel Events and Reporting Formats (continued)
Copyright  2007 Bosch Security Systems, Inc.

Zone Types

Event Description
Opening after Alarm event
by RPS.
Opening after Alarm event,
ID reported.
by Keyswitch
Panel Parameters Changed
Phone line voltage less than
3 volts for 40 seconds.
After Phone Line Fail event,
phone line voltage detected
at greater than 3 volts for 40
seconds.
Panel attempted call to
RPS, but was unsuccessful.
RPS attempted to connect
to panel but was not
successful.
RPS successfully
connected to and
disconnected from panel.
Normal start up or reset by
RPS.
Unexpected reset (reboot)
from Option Bus device.
(Timer)
Restoral from alarm,
4- Tamper
Tamper zone type.
Restoral from alarm,
5-
Emergency zone type.
Emergency
Restoral from alarm, Panic
6- Visible

zone type.

Panic
Restoral from alarm,
7-Invisible
Invisible zone type.
Panic
Restoral from alarm, 24-
8- Burglary
hour burglary zone types.

15- Door

Restoral from alarm, zone
11- Delay 1
types.

12- Delay 2

Restoral from alarm, zone
10-
types.
Keyswitch

13- Follower

14- Instant

Jammed condition detected
on premises RF receiver.
Jammed condition detected
on premises RF receiver
cleared.
P/N: 4998152533-02
PART V: REFERENCE MATERIALS
RPS
Status
Linked to
Event
Reports
Event
Group
10
10
12
R
12
R
12
R
12
R
R
R
R
12
R
16
R
16
R
R
16
R
16
R
R
8
8
8
8
8
8
8
9
R
9
R
Page 129