106 en | Area Wide Parameters
If a passcode is required for turning the system on, the user must also be assigned an
Authority Levels, page 158 with Restricted Open/Close = E (enabled) in order for O/C reports
to be restricted.
Open/Close Windows does not prevent restricted opening and closing reports from being
sent. Early or late designations are not added to opening/closing reports when they are sent
according to the rules for restricted opening/closing reports.
RPS Menu Location
Area Wide Parameters > Area/Bell Parameters, Open/Close Options > Restricted O/C
4.1.30

Part On O/C

Default: No
Selections:
This parameter determines if this area can send Part On, Instant and Part On, Delay closing
reports and normal opening reports to the central station.
This event is not suppressed by opening/closing windows.
RPS Menu Location
Area Wide Parameters > Area/Bell Parameters, Open/Close Options > Part On O/C
4.1.31

Exit Delay Restart

Default: Yes
Selections:
Yes - enable Exit Delay Restart.
No - do not restart Exit Delay.
The Exit Delay Restart feature automatically restarts exit delay when an end-user reenters the
premises before exit delay expires. For example, a home owner turns on (arms) their system,
leaves and closes the door, then realizes they forgot to pick up the car keys. When they open
the door to retrieve their keys, the control panel restarts exit delay, giving them plenty of time
to turn the system off.
With this parameter is set to Yes, following these steps restarts exit delay (Exit Delay Time,
page 94):
1.
2.
3.
Notice!
Exit delay restarts only one time
Exit Delay can only be restarted one time. Faulting the same point a again, or faulting another
point in the restarted exit delay does not restart the delay a second time.
RPS Menu Location
Area Wide Parameters > Area/Bell Parameters, Open/Close Options > Exit Delay Restart
4.1.32

All On- No Exit

Default: Yes
Selections:
2017.03 | 09 | F.01U.303.998
Yes - this area can send Part On opening and closing reports.
No - this area cannot send Part On opening and closing reports.
Turn the system All On or Part On.
Fault and restore a point (open and close a door) assigned to a Point Profile configured
for the Point Type, Part On, and a delayed alarm Point Response (4, 5, 6, 7, or 8). (Point
Profiles, page 182, Point Type, page 184, Point Response, page 184)
With exit delay still running, fault any point (open a door) assigned to a Point Profile
configured for the Point Type, Part On, and a delayed alarm Point Response (4, 5, 6, 7, or
8). Exit Delay restarts.