Control Panel
This function unbypasses individual points that are programmed either P## FA Returnable or
P## Bypass Returnable. Points within the Scope of the keypad are unbypassed where the
function is entered.
The control panel will respond to alarms/troubles and display point faults when a point is
unbypassed.
RPS Menu Location
User Configuration > User Keypad Functions > Unbypass a Point
9.3.24

Reset Sensor

Default: E
Selections:  - , E, P
This function resets sensors in areas within the Scope of the keypad.
RPS Menu Location
User Configuration > User Keypad Functions > Reset Sensors
9.3.25

Change Output

Default: P
Selections:  - , E, P
This function allows the user to manually set and reset any outputs installed in the system.
NOTE: The Change Outputs parameter also works with onboard outputs. Use the following
output numbers to toggle the onboard outputs:
RPS Menu Location
User Configuration > User Keypad Functions > Change Outputs
9.3.26

Remote Program

Default: P
Selections:  - , E, P
This function initiates Remote Account Manager sessions. When the phone is ringing at the
control panel, the user initiates this function to have the control panel seize the line.
Notice!
To comply with UL 864 requirements for Commercial Fire Systems, set this parameter to P.
Bosch Security Systems, Inc.
Enable (E) - Enable this function panel wide without requiring a passcode.
Passcode (P) - Require a passcode to enable this function panel wide.
Disable (-) - Disable this function panel wide regardless of the user's authority level.
Enable (E) - Enable this function panel wide without requiring a passcode.
Passcode (P) - Require a passcode to enable this function panel wide.
Disable (-) - Disable this function panel wide regardless of the user's authority level.
Enable (E) - Enable this function panel wide without requiring a passcode.
Passcode (P) - Require a passcode to enable this function panel wide.
Onboard Output A(1) > Output #253
Onboard Output B(2) > Output #254
Onboard Output C(3) > Output #255
Disable (-) - Disable this function panel wide regardless of the user's authority level.
Enable (E) - Enable this function panel wide without requiring a passcode.
Passcode (P) - Require a passcode to enable this function panel wide.
Program Entry Guide
User Configuration | en 155
2017.03 | 09 | F.01U.303.998