Rps Call Back; Rps Line Monitor - Bosch B9512G Program Entry Manual

Security system
Hide thumbs Also See for B9512G:
Table of Contents

Advertisement

72
en | Panel Wide Parameters
No - the control panel does not automatically contact RPS when the "Log % Full" threshold is
reached.
RPS Menu Location
Panel Wide Parameters > RPS Parameters > Contact RPS if Log % Full.
3.14.4

RPS Call Back

Default: No
Selections:
Notice!
When using the RPS Callback function, enter a "C" as the last digit in the RPS phone number
if DTMF dialing is used.
This parameter allows the control panel, after it has verified the RPS passcode, to provide an
additional level of security by hanging up and dialing the RPS phone number to call RPS at the
central station prior to allowing any upload or download.
RPS Menu Location
Panel Wide Parameters > RPS Parameters > RPS Call Back
3.14.5

RPS Line Monitor

Default: Yes
Selections:
This parameter enables a control panel that shares a phone line with an answering machine to
communicate with RPS at the central station even though the answering machine has
answered the phone. You must set Answer Armed, page 73 and/or Answer Disarmed, page
73, and the control panel must be in the proper armed state.
Notice!
If RPS Call Back, page 72 is set to Yes, the control panel hangs up the phone after the RPS
tone and a proper RPS passcode is identified, then it calls the RPS phone number.
Notice!
Set this parameter to No if it causes false seizures of the phone line, or if you are not using
RPS. This would indicate that a device using the same frequency tone is also using the phone
line to which the control panel is connected.
RPS Menu Location
Panel Wide Parameters > RPS Parameters > RPS Line Monitor
2017.03 | 09 | F.01U.303.998
Yes - when the control panel hears the proper RPS passcode, it hangs up the phone,
seizes the phone line, then dials the programmed RPS phone number Refer to RPS Phone
#, page 73. This ensures that only the control panel communicates with the RPS PC
connected to the dialed phone number.
No - the RPS session is initiated immediately; no call back is required. The control panel
engages in RPS sessions when called from any phone number and a proper RPS passcode
is identified.
Yes - this setting allows the control panel to communicate with RPS after the answering
machine has answered the phone.
No - use this setting if the control panel is not sharing the phone line with an answering
machine.