236 en | Automation / Remote App
13

Automation / Remote App

13.1

Automation Device

Default: None
Selections:
This parameter enables and selects the communication module to use exclusively for
automation communication.
RPS Menu Location
Automation / Remote App > Automation Device
13.2

Status Rate

Default: 0
Selections: 0 - 255
This parameter sets how often the default status information is sent to the Serial Interface
Module.
0:          Status information never sent unless requested.
1 – 255: Status information is sent at the interval programmed.
The Status information includes the current point status (normal or off-normal), the control
panel's area status (All On, All On Instant, Part On Delay Armed, Part On Instant, Disarmed,
Area Entry Delay, Part On Entry Delay, Area Exit Delay, Part On Exit Delay), the control panel
status (AC fail, battery missing, AC restore, battery low, and so on), and output status (output
on or output off).
Entries are in 500 millisecond increments. Therefore, if a 5 is entered, the Status information
is sent every 500 milliseconds (or ½ second). An entry of 10 would equal 1 second. If the
Status Rate is set to a value under 10 and there are 1 – 6 SDI devices connected to the
system, the fastest the control panel can send the Status information is approximately 1
second. In addition to this, if there are more than 6 SDI Devices connected to the control
panel, the fastest the control panel can send the information is approximately 1½ to 2
seconds.
RPS Menu Tree Location
Automation / Remote App > Status Rate
13.3

Automation Passcode

Default: Bosch_Auto
Selections: Up to 24 characters.
This parameter sets the passcode that must be entered before automation software can
connect to the control panel.
This parameter accepts up to 24 characters, but allows shorter passcodes.  The minimum
length is six characters.  The passcode is case-sensitive. The automation passcode must be
entered before any other automation commands will be accepted by the control panel.
2017.03 | 09 | F.01U.303.998
None.  Automation communication is disabled.
Mode 1 using onboard connection without TLS.
Mode 1 using a B42x module at SDI2 address 1.
Mode 1 using onboard connection with TLS.   
Mode 2 using an onboard connection or B42x module at SDI2 address 1, TLS or secure
UDP connection
Program Entry Guide
Control Panel
Bosch Security Systems, Inc.