Open/Close Options - Bosch D9412GV4 Program Entry Manual

Table of Contents

Advertisement

D9412GV4/D7412GV4/D7212GV4
NOTICE!
Silencing the bell resets A# Single Ring.
A# Bell Test
Default:
Selection:
Yes
No
Provides alarm output from the relay programmed at A# Alarm Bell after the Closing Report is
confirmed or the exit delay time expires.
Bell Test After Confirmation
In areas that send Opening and Closing Reports, the Bell Test occurs after the control panel
sends the Closing Report and receives an acknowledgment from the central station receiver.
For proper operation of the Bell Test after closing confirmation, the following rules apply:
Area Armed Confirmation
In areas that do not report opening and closing activity, the alarm bell relay output for this
area activates for 2 sec after exit time expires.
NOTICE!
Multiple Bell Tests occur: When more than one area is armed at the same time (such as using
the ARM ALL AREAS? function), the bell rings for 2 sec with a 2 sec pause between each bell
activation if all areas have the same exit delay time programmed. Otherwise, the Bell Test
occurs as each area arms and it completes its exit delay time.
When areas arm simultaneously and report to the central station, the Bell Test occurs as the
central station receiver confirms each area.
3.10.4

Open/Close Options

Programming determines if Opening, All Normal Closing, and Force Arm/Bypass Closing
Events are sent to the remote central station. Without remote reports, all control panel and
area arming (Closing Events) and disarming (Opening Events) default to local events.
Use this programming category to determine which opening and closing supervision
characteristics are needed.
There are three ways to generate reports from the control panel. You can generate reports by
account, by area, or a combination of both.
NOTICE!
Opening and Closing Events are sent only by users with the proper authority settings.
To suppress reports:
Bosch Security Systems, Inc.
No
Yes or No
Start Bell Test.
Do not start Bell Test.
The control panel must send Opening and Closing Reports to the central station.
Do not use restricted openings and closings or Opening and Closing Windows.
Use Opening/Closing Windows to suppress reports for a specified period of time and
then automatically turn them on again.
Use the Restricted O/C options. A Closing Report is sent if the user is force arming,
sending duress, or bypass arming. An Opening Report is sent if the user is disarming
during an alarm condition or unbypasses points when disarming. If the system is normal,
no Opening or Closing Report is sent.
Program Entry Guide
Panel and Area Wide Parameters | en
F.01U.218.312 | 04 | 2012.03
69

Advertisement

Table of Contents
loading

This manual is also suitable for:

D7412gv4D7212gv4

Table of Contents