C Key Custom Function; Manual Silent Alarm Audible On Comm Trouble - Bosch B9512G Program Entry Manual

Security system
Hide thumbs Also See for B9512G:
Table of Contents

Advertisement

124 en | Keypads
The "C" Key's default function is Manual Panic Alarm. To change the function, set this
parameter to "C" Key Custom Function. If the "C" key is configured to execute a custom
function, then the "C" Key Custom Function parameter must also be configured.
Notice!
Enabling the C Key Response for a panic alarm also enables the keypad CMD 9 response to
generate a panic alarm when you enter CMD 9 from any keypad that has this function
enabled.
Notice!
The "C" Key Custom Function option is not available with B942 touch screen keypads.
RPS Menu Location
Keypads > Global Keypad Settings > C Key Response
5.2.6

C Key Custom Function

Default:  Disabled
Selections:
This parameter specifies the custom function that is run when a "C" key is held and the "C"
key is configured to run a custom function.
If the custom function number is disabled and the "C" key is configured to run a custom
function, holding the "C" key generates an invalid key press response.
The number of custom functions supported varies based on the control panel type. Select the
CF# that corresponds to the custom function programmed in Custom Functions.
Notice!
The "C" Key Custom Function option is not available with B942 touch screen keypads.
RPS Menu Location
Keypads > Global Keypad Settings > C Key Custom Function
5.2.7

Manual Silent Alarm Audible on Comm Trouble

Default: No
Selections:
This parameter enables the Alarm Bell output to activate for the remaining Burg Bell time if a
keypad or RADION keyfob silent alarm fails in two attempts to transmit its report to the
configured destination.
The Alarm Bell outputs activated are the same outputs that would have been activated if the
keypad or RADION keyfob alarm had been configured as a panic alarm. The bell timer was
started when the silent alarm was generated so the Alarm Bell is only active for the configured
Burg Time minus the time it took to attempt to report twice.
2017.03 | 09 | F.01U.303.998
B9512G: Disabled, Function 128 to Function 159
B8512G: Disabled, Function 128 to Function 135
Yes   Enable the Alarm Bell to activate when the silent alarm event fails to reach central
station.
No    Disables the Alarm Bell from activating when the silent alarm fails to reach central
station.
Program Entry Guide
Control Panel
Bosch Security Systems, Inc.