Delay Response, Disarmed; Delay Response, Armed - Bosch B9512G Program Entry Manual

Security system
Hide thumbs Also See for B9512G:
Table of Contents

Advertisement

Control Panel
Use this parameter to configure the length of time (MM:SS) a disarmed control panel waits
after a point faults before reporting the event to the central station.
The control panel sends a Burg Supervisory report to the central station if the point remains
faulted during the entire period of time configured in this parameter. If the point is restored
during this time, no report is sent. The control panel does not indicate monitor delay at the
keypad.
Enable this feature to monitor a door, such as a trash compactor, jewelry case, or freezer that
should not be left open.
Notice!
Starting a walk test that includes controlled points, or arming the points' area will cancel the
monitor point timer. No report is sent after the configured time expires.
RPS Menu Location
Points > Point Indexes (point profiles) > Monitor Delay
10.3.32

Delay Response, Disarmed

Default: 00:00
Selections: 00:05 thru 60:00
00:00 = disabled
This parameter sets the length of time (MM:SS) the control panel waits after a disarmed point
faults before annunciating or reporting the fault. This parameter only applies to the following
point types when armed:
Use this feature to delay the effect of the following parameters:
Notice!
Point Response (D) Delay Alarm is not supported by Delay Response feature. So, when a
Delay Alarm results in an instant alarm, that alarm is not delayed by this feature.
RPS Menu Location
Points > Point Indexes (point profiles) > Delay Response Disarmed
10.3.33

Delay Response, Armed

Default: 00:00
Selections: 00:05 thru 60:00
00:00 = disabled
This parameter sets the length of time (MM:SS) the control panel waits after an armed point
faults before annunciating or reporting the fault. This parameter only applies to the following
point types when armed:
Bosch Security Systems, Inc.
Part On, page 203
Interior, page 204
Interior Follower, page 204
Point Response, page 184
Instant Alarm
Supervisory
Buzz on Fault, page 193
Watch Point, page 193
Output Response Type, page 194
Display as Device, page 194
Output, page 179
Program Entry Guide
Points | en 201
2017.03 | 09 | F.01U.303.998