Answer Rps Over Network; Rps Address Verification; Rps Network Address; Rps Port Number - Bosch B9512G Program Entry Manual

Security system
Hide thumbs Also See for B9512G:
Table of Contents

Advertisement

68
en | Panel Wide Parameters
3.12.2

Answer RPS Over Network?

Default: Yes
Selections:
This parameter determines if the control panel automatically accepts RPS initiated
connections through the onboard Ethernet communicator or a network interface module on
the SDI2 bus.
If this parameter is set no, RPS initiated connections can be accepted at a keypad by selecting
Answer from the RPS menu (Actions > RPS > Answer).
Notice!
Service Mode allows RPS connections over network
When the control panel is in service mode, the control panel automatically accepts RPS
initiated connections over the network, even if this parameter is set to No.
To place the control panel in installer mode, press and hold the control panel RESET button
until the Heartbeat LED flashes fast. Keypads show SERVICE MODE and prompt for the
installer passcode. Enter the installer passcode and press [ENTER].
RPS Menu Location
Panel Wide Parameters > SDI RPS/Enhanced Communication > Answer RPS Over Network
3.12.3

RPS Address Verification

Default: No
Selections:
When enabled, this parameter verifies that RPS connects to the control panel from a known IP
address.
This verification can be temporarily disabled by selecting ALLOW ANSWER in the MENU 34
menu.
RPS Menu Location
Panel Wide Parameters > SDI RPS/Enhanced Communication > RPS Address Verification
3.12.4

RPS Network Address

Default: Blank
Selections: IPv4 address or Hostname
This parameter sets the IP address or hostname for RPS.
Be sure to contact your network administrator to find out which IP Address or hostname your
RPS computer is connected to.
RPS Menu Location
Panel Wide Parameters > SDI RPS/Enhanced Communication > RPS Network Address
3.12.5

RPS Port Number

Default: 7750
Selections: 1 – 65535
This parameter is used as the destination UDP port for control panel-initiated RPS network
sessions.
2017.03 | 09 | F.01U.303.998
Yes - enables automatic RPS initiated connections over the network.
No - prevents automatic RPS initiated connections over the network.
Yes - this setting verifies that the incoming RPS IP address matches the address entered
in RPS Network Address, page 68.
No this setting allows RPS to connect to the control panel from any IP address. No
verification is performed.
Program Entry Guide
Control Panel
Bosch Security Systems, Inc.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B8512gB8512g-eB9512g-e

Table of Contents