Control Panel
When an abort alarm timer starts, it does not stop until an alarm silence operation is
performed, or the time expires. This feature does not apply to fire alarms or invisible point
alarms.
RPS Menu Location
Panel Wide Parameters > Miscellaneous > Abort Window
3.15.14

Passcode Length

Default: Disabled
Selections:
Select the number of digits allowed in all passcodes.
Notice!
To comply with SIA CP-01 False Alarm Reduction, set this parameter between 3 and 6 digits.
Refer to SIA CP-01 Verification for more information.
If the passcode length is changed and duplicate or unusable passcodes are created as a result,
a WARNING! Duplicate / Unusable Passcodes Present window opens.
Passcodes identified as a duplicate appear in bold red.
Passcodes identified as unusable (length is under or over the value entered in this parameter),
appear in bold blue.
To change a passcode:
1.
2.
3.
There are two option buttons that control how this parameter handles passcode entries:
Notice!
When the second option (Disable passcode length and store the data in this account) is
selected, RPS sets the SIA CP-01 Verification parameter to No and then notifies the RPS
operator with a Yes/No dialog for each of the following scenarios. Select Yes or No as
appropriate.
Notice!
Change in Passcode Length Parameter
RPS displays the following message dialog: "This operation will cause the Passcode Length to
be disabled, SIA CP-01 Verification parameter will be set to No and previously existing RPS
passcode data will be stored. Are you sure you want to continue?"
Bosch Security Systems, Inc.
Disabled
3, 4, 5, or 6 digits
Click the appropriate cell in the User Passcode column to select the passcode.
Press the [Backspace] key on your keyboard to clear the cell.
Enter the new passcode.
Save corrected passcodes: This option is selected by default. All passcodes marked as
duplicate or unusable must be fixed before you click OK to save the passcode
corrections.
Disable passcode length and store the data in this account: This option disables the
Passcode Length parameter and allows you to save passcodes of varying lengths in the
RPS account.