156 en | User Configuration
RPS Menu Location
User Configuration > User Keypad Functions > Remote Program
9.3.27

Go to area

Default: P
Selections:  - , E, P
This function temporarily switches the keypad's assignment to a different area. This can be
used to perform any function that can be performed by a keypad assigned to the area in
programming.
Users are limited to performing functions enabled by the authority level they have in the area
that the keypad is moved to. After fifteen (15) seconds of no activity at the keypad, the keypad
reverts back to the originally programmed area.
RPS Menu Location
User Configuration > User Keypad Functions > Move to Area
9.3.28

Display Panel Type and Revision

Default: E
Selections:  - , E, P
This function displays the control panel's software revision number in the keypad display.
RPS Menu Location
User Configuration > User Keypad Functions > Display Revision
9.3.29

Service Walk All Points

Default: P
Selections:  - , E, P
This function allows a user to walk test all points in the entire control panel regardless of the
Point Type.
24-Hour points left off-normal when exiting the Service Walk Test are bypassed. A trouble tone
sounds until it is silenced. The keypads alternate text with the Bypass indications.
Points 128 and 248 are not accessible by this function. This is normal. This function allows
viewing of extra points. Extra points can occur when:
RPS Menu Location
User Configuration > User Keypad Functions > Service Walk All Points
9.3.30

Change Skeds

Default: P
Selections:  - , E, P
2017.03 | 09 | F.01U.303.998
Disable (-) - Disable this function panel wide regardless of the user's authority level.
Enable (E) - Enable this function panel wide without requiring a passcode.
Passcode (P) - Require a passcode to enable this function panel wide.
Disable (-) - Disable this function panel wide regardless of the user's authority level.
Enable (E) - Enable this function panel wide without requiring a passcode.
Passcode (P) - Require a passcode to enable this function panel wide.
Disable (-) - Disable this function panel wide regardless of the user's authority level.
Enable (E) - Enable this function panel wide without requiring a passcode.
Passcode (P) - Require a passcode to enable this function panel wide.
Point Source is set to anything other than Unassigned,
Point Index is set to 0, or
At least two points are installed for the same Point Assignment on different Point
Sources.