Program The Wireless Keyfob Panic Function Table 19: (Optional); Program On-Board Outputs For The Table 20: Rf3334/Rf3334E Keyfob (Optional); Table 33: Panic Key C Selections; Table 34: Programming On-Board Keyfob Outputs (Address 2734 To 2736, Data Digit 2 When Data Digit 1 = *0) - Bosch DS7400XiV4-EXP Reference Manual

Wireless reference guide
Hide thumbs Also See for DS7400XiV4-EXP:
Table of Contents

Advertisement

DS7400XiV4-EXP | Wireless Reference Guide | 5.0
5.5
Program the Wireless Keyfob Panic Function (Optional)
The Panic function only operates if programmed in the control panel. Programming Address 3148 ("C" key) allows
you to disable or enable the Panic key on the keyfob for silent, pulsed, or steady alarm. Refer to Emergency Key
Programming: Program Addresses 3147-3148 in the DS7400Xi-EXP Reference Guide (P/N: 4998154963) for more
information.
If the control panel is set for Commercial Fire Mode, the values for the Panic Key might be forced to
different values. For more information, refer to Commercial Fire Mode Programming: Program Address
2733 in the DS7400Xi-EXP Reference Guide (P/N: 4998154963).
Address: 3148
Data Digit:
Address 3148, Data Digit 1: ____ (refer to Table 33; default = 0)
Address 3148, Data Digit 2: Must be 0
Default: 0
Selections: 0 to 3
5.6
Program On-Board Outputs for the RF3334/RF3334E Keyfob (Optional)
The RF3334/RF3334E Keyfob has two key outputs which you can program to drive the control panel's on-board
outputs. Use either key to drive any of the three on-board outputs, or any of the 24 custom programmable
outputs.
The operation of the Option key is the same on all keypads and keyfobs if they are assigned to the same area.
Addresses: 2734 to 2736
Data Digits:
Data Digit 1: Must = *0 for wireless keyfob outputs (refer to Table 35 for default values)
Data Digit 2: ____ (refer to Table 34 for options; refer to Table 35 for default values)
Selections: 0 to 4
Table 34: Programming On-Board Keyfob
Outputs (Address 2734 to 2736,
Data Digit 2 When Data Digit 1 = *0)
Options
RF3334/RF3334E
Disabled
Momentary
Option Key
Toggle
Option Key
Momentary
Auxiliary Key
Toggle
Auxiliary Key
Bosch Security Systems | 6/05 | 4998154962B
Table 33: Panic Key C Selections (Address 3148 Data Digit 1)
Select Option
Panic Key Disabled
Panic Key = Silent Alarm
Panic Key = Steady Alarm
Panic Key = Pulsed Alarm
Value
0
1
2
3
4
Adding Keyfobs
Value
0
1
2
3

Table 35: Address 2734 to 2736 Defaults

Output
Alarm
Programmable Output 1
Programmable Output 2
EN | 23
Address
Default
2734
6 3
2735
3 3
2736
2 3