Output Text; Output Text (Second Language); Hide From User - Bosch B9512G Program Entry Manual

Security system
Hide thumbs Also See for B9512G:
Table of Contents

Advertisement

Control Panel
This parameter guides the RPS operator with configuration rules, such as where the Octo-
output devices are allowed to be configured, and what output number ranges are permitted.
When a selection is grayed out it cannot be changed.
You can install a B308 Octo-output Module on particular Output number boundaries starting
at Output 11. Refer to B308 Octo-output Module switch settings, page 260.
Notice!
Use of IP Camera as Output Source is limited
Each IP Camera (1 to 16 for B9512, 1 to 8 for B8512) supports 4 outputs. You can select IP
Camera as Output Source for Outputs 11 to 14, 21 to 24, 31 to 34, ...161 to 164 only.
Do not select IP Camera as Output Source for Outputs 15 to 18, 25 to 28, 35 to 38, ...165 to
168.
RPS Menu Location
Output Parameters > Output Configuration > Output Source
8.3.2

Output Text

Default: Output #
Selections: Up to 32 alphanumeric characters
This parameter provides a description for the physical location of the point for use by
installation and service personnel. Enter up to 32 characters of text to describe the output.
Note:  To expand or collapse the list of Point numbers, use the arrows at the top of the RPS
screen.
RPS Menu Location
Output Parameter > Output Configuration > Output Text
8.3.3

Output Text (Second Language)

Default: Blank
Selections: Up to 32 alphanumeric characters
This parameter provides a description for the physical location of the point for use by
installation and service personnel. Enter up to 32 characters of text to describe the output.
Note:  To expand or collapse the list of Point numbers, use the arrows at the top of the RPS
screen.
RPS Menu Location
Output Parameter > Output Configuration > Output Text-Second Language
8.3.4

Hide From User

Default: No
Selections:
This parameter gives the installer the ability to hide outputs from user control.
Note:  To expand or collapse the list of Point numbers, use the arrows at the top of the RPS
screen.
Bosch Security Systems, Inc.
Keypad
ZONEX
When upgrading from an older control panel, Output Source defaults to ZONEX. Change
Output source to On-board for outputs 1, 2, and 3 to work properly.
Optionally, set the On-board outputs to ZONEX if output numbers 253, 254, and 255 are
desired.
Yes - The control panel denies access to this output for all users except the installer.
No - The control panel allows authorized end users to toggle the output manually at  a
keypad, or by using RSC, Automation Mode 1, or Automation Mode 2.
Program Entry Guide
Output Parameters | en 143
2017.03 | 09 | F.01U.303.998