Enter Key Output; Passcode Enter Function - Bosch B9512G Program Entry Manual

Security system
Hide thumbs Also See for B9512G:
Table of Contents

Advertisement

Control Panel
RPS Menu Location
Keypads > Keypad Assignments > Passcode Follows Scope
Further information
Scope, page 111
Area, page 178
Arm by Passcode, page 171
Disarm by Passcode, page 172
5.1.9

Enter Key Output

Default: 0 (for all keypad addresses)
Selections:
This parameter assigns an output to Passcode Enter Function, Cycle Output function.
When the Passcode Enter Function, page 113 is set to Cycle Output, and a user enters their
passcode and presses [Enter], the output assigned by this parameter cycles (activates for 10
seconds). Two events are added to the panel log: Output ### Set with User ID and, Output
### Reset without User ID.
Notice!
Do not share Enter Key Output with other output functions
The output you assign in this Enter Key Output parameter must not be assigned to any other
output function. Erroneous output operation can result.
You can use the Passcode Enter Function, Cycle Door and the Enter Key Output for a low-level
access control strike on a door. It does not shunt a point.
RPS Menu Location
Keypads > Keypad Assignments > Enter Key Output
Further information
Passcode Enter Function, page 113
5.1.10

Passcode Enter Function

Default: Arm/Disarm (for all KP addresses)
Selections:
Bosch Security Systems, Inc.
0 – no output assigned to Passcode Enter Function, Cycle Output.
B9512G: 1 to 599 – assigns output for Passcode Enter Function, Cycle Output.
B8512G: 1 to 99
Arm/Disarm - Passcode + [ENTER] starts All On Delay arming for all areas within the users
scope if the current area is disarmed. If the area is not disarmed (off), then all areas in
scope are disarmed.
Cycle Door - Passcode + [ENTER] cycles the door controller programmed in Assign Door,
page 114 for the Strike Time, page 230 duration, then actuates the users authorized post
access operations (Disarm, Perimeter Instant arm, or execute a Custom Function) if
enabled.
Cycle Output - Passcode + [ENTER] key activates Enter Key Output, page 113 for 10
seconds.
Auto Re-Arm - If the area assigned to the keypad is armed All On Delay, passcode +
[ENTER] starts Exit Delay. If the area is Off, passcode + [ENTER] does not arm, the area
remains off.
Login Only - Passcode + [ENTER] key logs in the user. Dual authentication not enforced.
Login/Disarm - Passcode + [ENTER] key logs in the user and all armed areas within the
users authorized scope are disarmed. Dual Authentication not enforced.
Program Entry Guide
Keypads | en 113
2017.03 | 09 | F.01U.303.998

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B8512gB8512g-eB9512g-e

Table of Contents