Printronix P7000 Series Maintenance Manual page 77

Line matrix printers
Hide thumbs Also See for P7000 Series:
Table of Contents

Advertisement

Table 4. P7000 ASCII (Spool) Error Messages List
Displayed Message
ERROR: CPLD NOT
PROGRAMMED
ERROR: DC PROGRAM
NOT VALID
ERROR: DRAM AT
ADDRESS XXXXXXXX
ERROR: EC PROGRAM
NOT VALID
Explanation
The Complex Programmable
Logic Device (CPLD) on the
controller board is not
programmed. The EC
cannot read the version bits
in the CPLD which tell the
EC which configuration
version is installed.
The printer cannot find the
data controller program or
the validation checksum is
corrupt.
The printer found a defective
memory location.
The printer cannot find the
engine controller program or
the validation checksum is
corrupt.
List Of Messages
Solution
Cycle power. If the message appears
again, replace the controller board.
Record the message and return it
with the defective board.
1. Download the program again
(page 247).
2. If the message appears, replace
the flash memory SIMM.
1. Replace the DRAM DIMM.
2. Power on the printer. If the
message appears, replace the
controller board. Record the
message and return it with the
defective board.
1. Download the program again
(page 247). If the message
occurs again, replace all flash
memory SIMMs.
2. Power on the printer. Download
the emulation. If the message
appears, replace the controller
board. Record the message and
return it with the defective board.
77

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents