Table 4. P7000 ASCII (Spool) Error Messages List
Displayed Message
DP FIFO Busy*
DRVR CIR BAD*
E00 EXE @ ADDR0
See User Manual
E01A TYPE 0x40
See User Manual
Explanation
There is a timing problem in
the Engine Controller
firmware.
Driver Circuit Bad: the
hammer coil count test
failed.
An illegal or unsupported
instruction was attempted in
the application program.
An illegal or unsupported
instruction was attempted in
the application program.
List Of Messages
Solution
1. Cycle Power. Run the print job
again. If the message appears,
download the emulation software
again (page 247).
2. Cycle power. Run the print job
again. If the message appears,
replace the flash memory.
3. Power on the printer. Run the
print job again. If the message
appears, replace the controller
board. Record the message and
return it with the defective board.
1. Cycle power. If the message
appears, press CLEAR.
2. Power off the printer. Remove the
shuttle cover. At the shuttle frame
assembly, disconnect the
hammer bank logic and power
cables. Power on the printer. If
"HB NOT INSTALLD" appears on
the LCD, replace the shuttle
frame assembly. If "HB NOT
INSTALLD" does not appear on
the LCD, replace the controller
board.
1. Cycle Power. Run the print job. If
the message appears again,
access the exception menu and
record the displayed messages
(page 222).
2. Power off the printer. Provide this
fault message and the messages
you recorded from the exception
menu to your next higher support
facility.
1. Cycle Power. Run the print job. If
the message appears again,
access the exception menu and
record the displayed messages
(page 222).
2. Power off the printer. Provide this
fault message and the messages
you recorded from the exception
menu to your next higher support
facility.