RS-232 Hardware Control
Product Reference Guide
Enables/disables use of the RS-232 CTS signal for flow control and/
or scan control.
Options are:
Disable — The scanner transmits to the host regardless of any
activity on the CTS line.
Enable CTS Flow Control — The CTS signal controls transmis-
sion of data to the host.
Enable CTS Scan Control — The CTS line must be active for
scanner to read and transmit data. While the CTS line is inac-
tive, scanner remains in a host- disabled state; following a
successful label transmission, the CTS signal must transition
to inactive and then to active to enable scanning for the next
label.
Enable Magellan SL CTS scan control — Emulates default
Magellan SL setting for this feature.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan bar code below or from the following page for the
desired setting. You'll need to cover any unused bar codes on
facing pages to ensure that the scanner reads only the bar
code you intend to scan.
3. Complete the programming sequence by scanning the SWITCH
bar code.
RS-232 HARDWARE CONTROL = DISABLE