Datalogic Magellan 8300 Product Reference Manual page 539

Hide thumbs Also See for Magellan 8300:
Table of Contents

Advertisement

Product Reference Guide
DataBar Expanded
Prefix must be ASCII characters ']e0'.
Label length excluding prefix characters must be at least 1
character. Maximum length is the maximum label size sup-
ported by the scanner.
Example: ']e001900123456789083103001750'.
I 2 of 5
Check character must be included in label data.
Label length including check characters and excluding prefix
characters must meet requirements imposed by the main
scanner's fixed or variable label length control for this sym-
bology type.
Prefix must be ASCII characters ']I0', ']I1' or ']I2' (other prefixes
specify different check character properties which are not
supported).
Example: ']I10123456789'.
Standard 2 of 5
Check character must be included in label data.
Label length including check characters and excluding prefix
characters must meet requirements imposed by the main
scanner's fixed or variable label length control for this sym-
bology type.
Prefix must be an ASCII character ']S0' (other prefixes specify
different check character properties which are not supported).
Example: ']S00123456789'.
Code 128 / EAN128
Prefix must be either ASCII characters ']C0', ']C1' or ']C2'.
Label length excluding prefix character must meet require-
ments imposed by the main scanner's fixed or variable label
length control for this symbology type.
If EAN-128 Symbology is Enabled and prefix is ']C1', label will
be identified as an EAN128 otherwise it is identified as a Code
128.
A prefix of ']C0' designates that no function code is present in
the 1st or 2nd character position.
A prefix of ']C2' designates that a function code 1 is present in
the 2nd character.
Example : ']C0Code_128.Test'.
527

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magellan 8400

Table of Contents