Product Reference Guide
DataBar Expanded
•
Prefix must be ASCII characters ']e0'.
•
Label length excluding prefix characters must be at least 1
character. Maximum length is the maximum label size sup-
ported by the scanner.
•
Example: ']e001900123456789083103001750'.
I 2 of 5
•
Check character must be included in label data.
•
Label length including check characters and excluding prefix
characters must meet requirements imposed by the main
scanner's fixed or variable label length control for this sym-
bology type.
•
Prefix must be ASCII characters ']I0', ']I1' or ']I2' (other prefixes
specify different check character properties which are not
supported).
•
Example: ']I10123456789'.
Standard 2 of 5
•
Check character must be included in label data.
•
Label length including check characters and excluding prefix
characters must meet requirements imposed by the main
scanner's fixed or variable label length control for this sym-
bology type.
•
Prefix must be an ASCII character ']S0' (other prefixes specify
different check character properties which are not supported).
•
Example: ']S00123456789'.
Code 128 / EAN128
•
Prefix must be either ASCII characters ']C0', ']C1' or ']C2'.
•
Label length excluding prefix character must meet require-
ments imposed by the main scanner's fixed or variable label
length control for this symbology type.
•
If EAN-128 Symbology is Enabled and prefix is ']C1', label will
be identified as an EAN128 otherwise it is identified as a Code
128.
•
A prefix of ']C0' designates that no function code is present in
the 1st or 2nd character position.
•
A prefix of ']C2' designates that a function code 1 is present in
the 2nd character.
•
Example : ']C0Code_128.Test'.
527