MSI/Plessey Length 1

444
Length 1 is the minimum label length if in variable length mode, or
the first fixed length if in fixed length mode (see MSI/Plessey
Length Control on page 443
and data characters.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code, SET MSI/PLESSEY LENGTH 1 on page 444
below. You'll need to cover any unused bar codes on this and
the facing page to ensure that the scanner reads only the bar
code you intend to scan.
3. Scan the appropriate digits from the keypad in Appendix C
that represent the desired label length. The selectable range
for this option is 004 to 016. Pad all single and double digit
numbers with leading zeroes to yield a three-digit entry (004-
016).
4. Complete the programming sequence by scanning the SWITCH
bar code.
) . Length includes the barcode's check