Error
Probable Cause
Code
0
Configuration
Blinking
1
Configuration Error
2
Interface Board
3
Motor
4
Horizontal Laser
5
Vertical Laser
6
Digital Board
7
Scale
8
Remote Display
A
Control Button Stuck
B
Hardware ID
C
Scale Calibration
E
CPLD ID
Decimal
3.3 V Present
Point
a. If only one laser is non-functional, the scanner may continue to work (this is a configurable fea-
ture); however, the 7-segment display will show the error code indicating the failed laser. If
both lasers have failed, the 7-segment display will display either a 4 or a 5, and the scanner will
cease to function until serviced. No alternate blinking of lamps will occur if only one laser has
failed.
70
Table 2. Error Codes
Corrective Action
No POS interface has been selected (Null interface). See Chap-
ter 6, Interface Type to select the required interface using pro-
gramming bar codes.
See Chapter 6, Programming, for details about configuring the
scanner using programming bar codes.
Unplug unit and call technical support personnel.
Unplug unit and call technical support personnel.
a
Call technical support personnel.
a
Call technical support personnel.
Unplug unit and call technical support personnel.
See the topic Scale Error Reporting on page 72 in this chapter
for problem identification and corrective actions.
Connect the Remote Display. If necessary, replace display or
cable. Alternatively, you can disable the Remote Display using
the programming procedures described in Chapter 6.
Check to see if either of the buttons is stuck; free it if possible.
If neither button is stuck, call technical support personnel.
Call technical support personnel.
Calibrate scale or call technical support personnel.
Call technical support personnel.
If not lit, call technical support personnel