Datalogic Handheld Data Format Requirements - Datalogic Magellan 8300 Product Reference Manual

Hide thumbs Also See for Magellan 8300:
Table of Contents

Advertisement

Datalogic Handheld Data Format Requirements

516
The following sections describe label transmission formats that are
typically observed in factory configurations of Datalogic handheld
scanners.
DataBar Omnidirectional
Prefix must be ASCII characters 'R4'
Check character must be included in label
Application identifier "01" must follow the prefix and preceed
the base label
Label length excluding prefix characters must be 16 charac-
ters.
Example: 'R40101044123456789'
DataBar Expanded
Prefix must be ASCII characters 'R4'
Check character must be included in label
UPC-A
System number must be included in label data.
Check digit must be included in label data and is assumed to
be correct.
Prefix must be an ASCII character 'A' - total length including
prefix must be 13.
Example: 'A060992011187'.
UPC-A with 2-Digit Supplemental
System number must be included in label data.
Check digit must be included in label data and is assumed to
be correct.
Supplemental data is appended to base label.
Prefix must be an ASCII character 'A' - total length including
prefix must be 15.
Example: 'A06099201118712'.
UPC-A with 5-Digit Supplemental
System number must be included in label data
Check digit must be included in label data and is assumed to
be correct
Prefix must be an ASCII character 'A' - total length including
prefix must be 18
Example: 'A06099201118712345'