Product Reference Guide
Standard 2 of 5
•
Check character must be included in label data.
•
Label length including check characters and excluding prefix
characters must meet requirements imposed by the main
scanner's fixed or variable label length control for this sym-
bology type.
•
Prefix must be an ASCII character 's'.
•
Example: 's0123456789'.
Codabar
•
Check character must be included in label data.
•
Label length including check character and excluding prefix
character must meet requirements imposed by the main scan-
ner's fixed or variable label length control for this symbology
type.
•
Prefix must be an ASCII character '%'.
•
Start stop character sets must meet the matching requirement
set forth by the scanner configuration item
Character Match
•
Start stop character sets must be of the form ABCD/ABCD and
must be included in the label.
•
Example: '%s$99.95s' (the lower case 's' at each end of the
example is a placeholder for the start stop character set).
Code 128
•
Prefix must be an ASCII character '#'.
•
Label length excluding prefix character must meet require-
ments imposed by the main scanner's fixed or variable label
length control for this symbology type.
•
Function characters may be transmitted as a hexadecimal
value 8x. Where x correlates to function characters 1 thru 4 as
follows:
•
x80 = function code 1
•
x81 = function code 2
•
x82 = function code 3
•
x83 = function code 4
•
For Code 128 programming labels the format is of the general
form '#/82nnnnn/r ' - /82 is hexadecimal 82 and /r is carriage
return.
•
Example: '#Code_128.Test'.
.
Codabar Start Stop
521