Datalogic Magellan 8300 Product Reference Manual page 75

Hide thumbs Also See for Magellan 8300:
Table of Contents

Advertisement

NOTE
L-Shaped
Platter
Product Reference Guide
2. If the top edge of the platter is blocked, you may find it
easier to use a coin to lift up an edge of the platter as
shown in
Figure 37
or other exposed edge.
Use caution to avoid damage to the now exposed horizontal and
Vertical Scan Windows. If cleaning of these windows is neces-
sary, use a nonabrasive, mild, water-based glass cleaner and
paper towels or lint-free cleaning tissues and take care to avoid
scratching these windows (damage to the windows can degrade
scanning performance).
3. The Vertical Scan Window is held in place by two tabs
each on its top and bottom edges. To remove it, care-
fully push out on the top as shown in
out. Carefully dispose of any damaged glass.
Figure 38. Vertical Scan Window Removal/Replacement
4. Fully seat the new Vertical Scan Window into the window
channel within its bottom retention tabs. Tilt the window
in to engage the two tabs at the top of the retainer and
carefully snap the window to secure it in place.
5. Clean both sides of the new Vertical Scan Window using
a paper towel or lint free cleaning tissues dampened
with a mild, water-based glass cleaner. DO NOT use
abrasive cleaners or pads.
Operational Maintenance
b, then grasp the platter vertical bezel
Vertical
Bezel
Vertical
Window
and lift it
Figure 38