DataBar Expanded Length 1
356
Length 1 is the minimum label length if in variable length mode, or
the first fixed length if in fixed length mode (see DataBar Expanded
Length Control on page 355
and data characters.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code, SET DataBar Expanded LENGTH 1 on page
356 below. You'll need to cover any unused bar codes on this
and the facing page to ensure that the scanner reads only the
bar code you intend to scan.
3. Scan the appropriate digits from the keypad in Appendix C
that represent the desired label length. The selectable range
for this option is 01 to 74. Pad all single and double digit
numbers with leading zeroes to yield a three-digit entry (001-
074).
4. Complete the programming sequence by scanning the SWITCH
bar code.
) . Length includes the barcode's check
SET DataBar Expanded LENGTH 1
Magellan™ 8300/8400