Datalogic Magellan 8300 Product Reference Manual page 86

Hide thumbs Also See for Magellan 8300:
Table of Contents

Advertisement

SELFTEST
START
Does the
7-segment
display show
0
?
YES
No interface selected
(Null Interface).
Select an interface.
Go to EAS System
flowchart
Does the
7-segment
display show
9.
?
74
Figure 42. Problem Isolation: Selftest
Does the
NO
7-segment
display show
1.
?
NO
Does the
7-segment
display show
2. or 3.
?
NO
Does the
7-segment
display show
4. or 5.
?
NO
Does the
7-segment
display show
7.
?
NO
YES
Does the
NO
7-segment
display show
8.
?
NO
Does the
Remote Display
show -0- or an error
(E__#)
?
NO
Unit passes Selftest
Scan the Factory
YES
Defaults bar code in
Section 6 to enable the
default configuration
file. Restart the unit.
YES
Call Tech Support
Error code 4. indicates a failed
horizontal VLDM (laser) assembly,
while 5. indicates a failed vertical
VLDM. If configured to do so 1 , the
YES
scanner will remain operational
with only one of these lasers until
the unit can be serviced. If both
lasers have failed, the unit will no
longer function.
YES
Call Tech Support
YES
Go to Remote Display
flowchart
YES
Go to Scale flowchart
1
Refer to the feature Laser Failure
Mode in Section 6.
Does the
YES
7-segment
display show
1.
?
NO
Magellan™ 8300/8400

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magellan 8400

Table of Contents