Datalogic Magellan 8300 Product Reference Manual page 97

Hide thumbs Also See for Magellan 8300:
Table of Contents

Advertisement

Product Reference Guide
Figure 48. Calibration Switch Access
Spider
4. Press and release the Calibration Switch to place the scanner/
scale in Calibration Mode. (The scanner/scale will sound a a
series of rapid beeps indicating it is in Calibration Mode.) If the
motor was spinning when you initiated Calibration Mode, the
motor will stop and the Yellow LED will begin flashing indicat-
ing the scale is in Calibration Mode.
is present) will show the message "ESCL" (empty scale).
5. Reinstall the weigh platter.
6. Press the Zero Push Button. The Yellow LED will go out for
approximately 10 seconds (or less).
Remote Display will alternately display
until the scale is ready to proceed.
7. When the scale is ready, the Yellow LED will begin blinking
again.
The Remote Display (if one is present) will show the
message "Ad20 (add twenty pounds)" or "Ad10 (add ten kilo-
(The scanner/scale will also sound one tone if the
grams)."
scale is weighing in kilograms or two tones for pounds.) Place
the correct weight (twenty pounds for calibration in pounds, or
ten kilograms for metric calibration) from the Field Standard
Weight set on the center of the weighing area and press the
Zero Push Button again.
Calibrating the Scale (Pounds & Kilograms)
Calibration
Switch
The Remote Display (if one
If one is present, the
and
85