Code 39 Check Character Calculation

NOTE
362
Enables/disables calculation and verification of an optional Code 39
check character. When disabled, any check character in label is
treated as a data character.
If check calculation is disabled, the risk is increased that a misread can
occur.
In particular, if you are using variable length stitching, it is important
to use check character calculation to prevent misreads.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan either the enable or disable bar code below. You'll need
to cover any unused bar codes on this and the facing page to
ensure that the scanner reads only the bar code you intend to
scan.
3. Complete the programming sequence by scanning the SWITCH
bar code.
CODE 39 CHECK CHARACTER CALCULATION = DISABLE
CODE 39 CHECK CHARACTER CALCULATION = ENABLE