Checking The Photointerrupters; Using Service Mode - Canon 1000 Service Manual

Color laser copier
Hide thumbs Also See for 1000:
Table of Contents

Advertisement

4
Checking the
Photointerrupters
The CLC1000 allows you to use a conventional
meter or service mode when checking its
photointerrupters.
1. Using a Tester
1) Set the tester to the 30VDC range.
2) Connect the – probe of the tester to J101-7
(GND) of the DC control PCB.
3) Connect the + probe to the terminals (on the
DC controller PCB or the deck controller PCB)
shown on the pages that follow.
4) Make checks according to the instructions
given.
DISP
COUNTER
ADJUST
FUNC
OPTION
TEST
COPYRIGHT © 2001 CANON INC.
<M> SENSOR
<S>
800000H
xxxxxxxx
800001H
xxxxxxxx
800002H
xxxxxxxx
800003H
xxxxxxxx
800004H
xxxxxxxx
800005H
xxxxxxxx
Address
bit 7
bit 0
CANON CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
7. TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS

2. Using Service Mode

1) Start service mode.
2) Press 'DISP'.
3) Press 'SENSOR'.
4) Make checks as indicated next page.
<R>READY
<P>READY
801000H
xxxxxxxx
801001H
xxxxxxxx
801002H
xxxxxxxx
801003H
xxxxxxxx
801004H
xxxxxxxx
801005H
xxxxxxxx
<F>
802000H
xxxxxxxx
802001H
xxxxxxxx
802002H
xxxxxxxx
802003H
xxxxxxxx
802004H
xxxxxxxx
802005H
xxxxxxxx
7-47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1000s3100

Table of Contents