Adjusting The Separation Roller Pressure - Canon 1000 Service Manual

Color laser copier
Hide thumbs Also See for 1000:
Table of Contents

Advertisement

4. MECHANICAL SYSTEM
3)
Remove the two screws [4], and remove the
separation roller unit [3].
[3]
Figure 4-310B
4)
Remove the two E-rings [5] (resin).
5)
Pull out the separation roller shaft [6], and
remove the separation roller [7].
[5]
[7]
Figure 4-311B
4-30
COPYRIGHT © 2001 CANON INC.
[4]
[6]
CANON CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
5. Adjusting the Separation Roller
Pressure
1)
Remove the pick-up assembly.
2)
Remove the screw [2], and remove the lower
guide [1].
[1]
Figure 4-312B
3)
If double-feeding or pick-up faults occur during
pick-up operation, adjust the position of the
pressure spring [4] of the separation roller [3].
• If double-feeding occurs, hook the spring on
A.
• If pick-up faults occur, hook the spring on B.
[3]
Figure 4-313B
[2]
B
A
[4]