7. TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
6) Fit the scanner cable on the pulley and the hook as indicated in Figure 7-219.
[2]
7) Remove the screw [3] used in step 5).
8) Loosen the screw on the mirror positioning tool
(FY9-3002-000), and extend the arm [6] fully.
[6]
Figure 7-220
7-14
COPYRIGHT © 2001 CANON INC.
[6]
Figure 7-219
CANON CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
[1]
[3]
Fix temporarily.
[5][8]
[4]
9) Set the mirror positioning tool [7] between the
No. 1 mirror mount and the No. 2 mirror mount;
then, insert the pin [8] that comes with the mir-
ror positioning tool.
[8]
Figure 7-221
Put the steel ball
into the hole.
[7]