11. Removing the Fixing Thermal
Switch (lower)
1)
Remove the lower fixing roller (See chapter 4.
X. FIXING SYSTEM, A-6. Removing the
Lower Fixing Roller).
2)
Remove the two screws [1], and remove the
fixing thermal switch [2] (lower).
Figure 4-1020A
12. Removing the Oil Filter
1)
Remove the fixing assembly (See chapter 4.
X. FIXING SYSTEM, A-1. Removing the
Fixing Assembly).
2)
Remove the oil filter [1].
Figure 4-1021A
COPYRIGHT © 2001 CANON INC.
[1]
[2]
[1]
CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
4. MECHANICAL SYSTEM
13. Removing the Oil Bottle
1)
Remove the fixing assembly (See chapter 4.
X. FIXING SYSTEM, A-1. Removing the
Fixing Assembly).
2)
Remove the screw [1], and remove the fixing
assembly positioning plate (front) [2].
3)
Remove the screw [3], and remove the oil
bottle fixing plate [4].
[1]
[3]
[4]
Figure 4-1022A
4)
While lifting the front of the oil pan, remove the
oil bottle.
[2]
4-101