4. MECHANICAL SYSTEM
5)
Spread paper, and remove the toner which
has collected on the surface of the sensor
cover [3] and the exposed area of the shutter
assembly [4] with a blower brush.
Take extra care to prevent deforma-
tion. The shutter assembly is very
fragile.
[3]
Figure 4-904E
6)
Pull the solenoid arm [5] with a finger, and
open the shutter; then, clean the sensor face
[6] with a blower brush.
Do not apply excessive force when
cleaning the sensor face. Use light
tapping motions.
[5]
Figure 4-905E
4-92
COPYRIGHT © 2001 CANON INC.
[4]
[6]
[4]
CANON CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
7)
Put the solenoid arm back into its initial
position with a finger; then, close the shutter.
8)
After installing the SALT sensor, execute
'FUNC > INSTALL > WINCLR-Y/M/C/K' in
service mode.
3. Disassembling and Cleaning the
Inside of the SALT Sensor Unit
1)