Env-Set (Setting Operation Conditions For The Cassette Heater) - Canon 1000 Service Manual

Color laser copier
Hide thumbs Also See for 1000:
Table of Contents

Advertisement

7. TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS

10. ENV-SET (setting operation conditions for the cassette heater)

DISP
COUNTER
ADJUST
FUNC
OPTION
TEST
Item
BODY °C
Indicates the machine internal temperature measured
by the environment sensor.
BODY %
Indicates the machine internal humidity measured by
the environment sensor.
BODY g
Indicates the machine internal humidity absolute value
(g) measured by the environment sensor.
>
Indicates the present environment.
ENV-A~G
Sets ON/OFF of the cassette heater.
OFF
Sets to OFF for all environment.
The settings of 'ENV-SET' are stored as soon as the CPU on the DC controller PCB is supplied with
power (i.e., when the power plug is connected to the power outlet), and will be renewed every 8 hr.
7-242
COPYRIGHT © 2001 CANON INC.
<M>
<S>
ENV-SET
BODY
26
˚C
%
BODY
48
BODY
g
1016
Description
CANON CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
<R>
<P>
READY
ENV-A
ENV-B
290g
>
ENV-C
580g
ENV-D
1050g
1500g
ENV-E
ENV-F
1800g
ENV-G
2160g
OFF
<F>
READY
USER
0g
to
290g
OFF
to
580g
OFF
to
1050g
OFF
1500g
OFF
to
to
1800g
ON
to
2160g
ON
ON
to
Remarks
Same as the reading
under 'DISPLAY' >
'ANALOG'.
The heater will turn on if
the internal humidity
absolute value exceeds
the setting.