CHAPTER 6 TROUBLESHOOTING

2.10 Checking the Photointerrupters

The machine allows the use of a conventional meter or its service mode for checks on its
photointerrupters:
a. Using a Meter
1) Set the meter range to 30 VDC.
2) Connect the - probe of the meter to GND of the DC controller PCB.
3) Connect the + probe of the meter to the terminal (DC controller PCB) indicated in the
table that follows.
4) Make checks as indicated.
b. Using Service Mode
1) Start service mode (CPEOR>I/O), and check the corresponding address.
Take full care. The sensor goes on and off, at times causing the motors and
the like to operate.
6-58
COPYRIGHT© 2001 CANON INC.
2000 2000 2000 2000
CANON iR105 REV.0 JULY 2001