7. TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
1. If the self diagnosis mechanism
has been activated, you can reset
REF.
the machine by turning its power
switch off and then on.
This, however, does not apply to
'E000'; if allowed with the ther-
mistor out of order, such would
heat and damage the fixing roller.
2. If 'E005' (ADD CLEANING BELT)
is indicated, replace the cleaning
web and execute 'E005-RLS' of
'FUSER' under 'FUNC' in service
mode.
3. Even after clearing the E indication
by turning off the power switch, a
description of the last E indication
may be checked using 'JAM/ER-
ROR' under 'DISPLAY'in service
mode.
•
Clearing E000
1) Start service mode, and select 'FUSER' under
'FUNC'.
2) Press 'E000-RLS'.
3) Turn off and then on the power switch.
•
Clearing E005
1) Start service mode, and select 'FUSER' under
'FUNC'.
2) Press 'E005-RLS'.
3) Turn off and then on the power switch.
•
Clearing E075
1) Start service mode, and select 'F-MISCp' un-
der 'FUNC'.
2) Press 'E075-RLS'.
3) Turn off and then on the power switch.
7-316
COPYRIGHT © 2001 CANON INC.
•
Clearing 'E004'
1) Turn off the power switch.
2) Disconnect and connect the power plug from
and to to the power outlet.
3) Turn on the power switch.
CANON CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)