4. MECHANICAL SYSTEM
IX. PROCESS UNIT
SYSTEM
A. Process Unit
1. Sliding Out the Process Unit
1)
Shift down the releasing lever [1] of the
transfer unit to release the transfer belt from
the photosensitive drum.
Figure 4-901A
2)
Lift the hopper unit.
3)
Remove the four primary charging assemblies
[2].
Figure 4-902A
4-80
COPYRIGHT © 2001 CANON INC.
[1]
[2]
CANON CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
If you have removed the primary
charging assembly, be sure to place
it so that the grid face is up.
4)
Remove the four positioning knobs [3] of the
photosensitive drum. (Turn the smaller knob
in the middle counterclockwise.)
Figure 4-903A
5)
Remove the two screws [5] of the process unit
[4].
[5]
Figure 4-904A
[3]
[4]
[5]