Canon 1000 Service Manual page 733

Color laser copier
Hide thumbs Also See for 1000:
Table of Contents

Advertisement

Code
Triac (short circuit)
E004
• Cleaning web (inside fixing
assembly; taken up)
E005
• Web length sensor (PS36; faulty)
• DC controller PCB (faulty)
• Fixing drawer connector (fault)
E006
• Fixing lever switch (SW5; fault)
• DC controller PCB (fault)
• Drum drive system (overload)
E012
• Drum motor (M21; error)
• DC controller PCB (faulty)
• Waste toner feeding motor (faulty)
• Waste toner feeding screw
(rotation fault)
E013
• DC controller PCB (faulty)
E014
• Fixing motor (M9; error)
• DC controller PCB (faulty)
• Pick-up motor (M10; faulty)
• DC controller PCB (faulty)
E015
• Duplexing feeding motor (M19;
E017
faulty)
• DC controller PCB (faulty)
• Polishing/oil removing motor
E018
(M15; faulty)
• DC controller PCB (faulty)
COPYRIGHT © 2001 CANON INC.
Cause
CANON CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
7. TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
0001
The triac is ON after the CPU on the
DC controller PCB has turned ON the
fixing heater triac drive signal.
0002
The triac is ON after the microproces-
sor on the DC controller PCB has
turned OFF the triac drive signal for the
drum heater.
The cleaning web solenoid has turned ON 270
times after the web length sensor detected the
lever.
0001
The fixing drawer connector connec-
tion signal CONNECT goes '0' when
the front cover is closed (i.e., the
drawer connector is disconnected).
0002
The fixing lever switch signal F-KBLK
goes '1' when the front cover is closed
(i.e., the fixing knob is not set).
0001
The rotation speed of the motor has
deviated from a specific value for 0.1
sec or more.
0001
The rotation speed of the waste toner
feeding motor has deviated from a
specific value for 0.1 sec or more (PLL
signal '0').
0002
The waste toner lock detection switch
(SW4) has been pressed for 0.1 sec or
more.
The rotation speed of the motor has deviated
from a specific value for 0.1 sec or more.
• The clock pulses of the pick-up motor
cannot be detected.
• The rotation speed of the motor has deviated
from a specific speed for 0.1 sec or more.
• The rotation speed of the duplexing feeding
motor has deviated from a specific value for
0.1 sec or more (PLL signal '0').
• The rotation speed of the polishing/oil
removing motor has deviated from a specific
value for 0.1 sec or more.
Description
7-297

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1000s3100

Table of Contents