7. TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
3
Adjusting the Tension on the
Drive Belt of the Transfer Belt
Motor
1) Make adjustments so that the gap of the ad-
justing screw [1] of the transfer belt motor is 3.5
±0.3 mm.
Figure 7-238
4
Adjusting the Position of the
Transfer Belt-Related Sole-
noid
a. Positioning the Transfer Cleaning Blade
Solenoid (SL6)
Fix the solenoid in place by butting the pin [1] of
the slider against the angular hole end A of the so-
lenoid mount while the plunger of the solenoid is
pulled.
A
Figure 7-239
7-24
COPYRIGHT © 2001 CANON INC.
b. Adjusting the Position of the Transfer
between the solenoid arm and the solenoid mount
base is 17.8 ±0.3 mm when the plunger of the sole-
noid is pulled.
[1]
3.5±0.3mm
c. Adjusting the Position of the Polishing
cated in Figure 7-253 is 2.5 ±0.3 mm when the so-
lenoid arm is pulled by the spring.
[1]
CANON CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
Blade Solenoid (SL7)
Fix the solenoid in place so that the distance
Figure 7-240
Roller Solenoid (SL18)
Fix the solenoid in place so that the stroke indi-
Figure 7-241
17.8±0.3mm
2.5±0.3mm