ethernet cfm mep
Create an MEP.
S-Series, S4810
Syntax
ethernet cfm mep {up-mep | down-mep} domain {name | level} ma-
name name mepid mep-id
Parameters
[up-mep | down-
mep]
domain [
level ]
ma-name
mepid
Defaults
none
Command Modes
INTERFACE
Command History
Version 8.3.7.0
Version 8.3.1.0
ethernet cfm mip
Create a maintenance intermediate point (MIP).
S-Series, S4810
Syntax
ethernet cfm mip domain {name | level} ma-name name
Parameters
domain [
level ]
ma-name
Defaults
none
206
Specify whether the MEP is up or down facing.
•
Up-MEP: monitors the forwarding path internal to a bridge on
the customer or provider edge; on Dell Force10 systems, the
internal forwarding path is effectively the switch fabric and
forwarding engine.
•
Down-MEP: monitors the forwarding path external to another
bridge.
name |
Enter the keyword domain and then enter the domain name or
domain level.
name
Enter the keyword ma-name and then enter the name of the
maintenance association.
mep-id
Enter an MEP ID. The range is 1 to 8191.
Introduced on the S4810.
Introduced on the S-Series.
name |
Enter the keyword domain and then enter the domain name or
domain level.
name
Enter the keyword ma-name and then enter the name of the
maintenance association.