Command Line Interface Reference for the ProSafe 7300 Series Layer-3 Switches, Software Ver-

14.3.3 ip irdp holdtime

This command configures the value, in seconds, of the holdtime field of the router
advertisement sent from this interface. The holdtime range is the value of
<maxadvertinterval>
Default
Format
Mode
14.3.3.1 no ip irdp holdtime
This command configures the default value, in seconds, of the holdtime field of the router
advertisement sent from this interface.
Format
Mode

14.3.4 ip irdp maxadvertinterval

This command configures the maximum time, in seconds, allowed between sending router
advertisements from the interface. The range for maxadvertinterval is 4 to 1800 seconds.
Default
Format
Mode
14.3.4.1 no ip irdp maxadvertinterval
This command configures the default maximum time, in seconds.
Format
Mode

14.3.5 ip irdp minadvertinterval

This command configures the minimum time, in seconds, allowed between sending router
advertisements from the interface. The range for minadvertinterval is three to the value of
maxadvertinterval.
Default
Format
Mode
14-20
to 9000 seconds.
3 * maxinterval
ip irdp holdtime <maxadvertinterval-9000>
Interface Config
no ip irdp holdtime
Interface Config
600
ip irdp maxadvertinterval <4-1800>
Interface Config
no ip irdp maxadvertinterval
Interface Config
0.75 * maxadvertinterval
ip irdp minadvertinterval <3-maxadvertinterval>
Interface Config
v1.0, December 2005