Command Line Interface Reference for the ProSafe 7300 Series Layer-3 Switches, Software Ver-
quiet-period: Sets the value, in seconds, of the timer used by the authenticator state
machine on this port to define periods of time in which it will not attempt to acquire a
supplicant. The quiet-period must be a value in the range 0 - 65535.
tx-period: Sets the value, in seconds, of the timer used by the authenticator state machine
on this port to determine when to send an EAPOL EAP Request/Identity frame to the
supplicant. The quiet-period must be a value in the range 1 - 65535.
supp-timeout: Sets the value, in seconds, of the timer used by the authenticator state
machine on this port to timeout the supplicant. The supp-timeout must be a value in the
range 1 - 65535.
server-timeout: Sets the value, in seconds, of the timer used by the authenticator state
machine on this port to timeout the authentication server. The supp-timeout must be a
value in the range 1 - 65535.
Default
Format
Mode
11.1.13.1 no dot1x timeout
This command sets the value, in seconds, of the timer used by the authenticator state
machine on this port to the default values. Depending on the token used, the corresponding
default values are set.
Format
Mode

11.1.14 dot1x user

This command adds the specified user to the list of users with access to the specified port
or all ports. The
Format
Mode
Port-Based Access and Authentication Commands
reauth-period: 3600 seconds
quiet-period: 60 seconds
tx-period: 30 seconds
supp-timeout: 30 seconds
server-timeout: 30 seconds
dot1x timeout {{reauth-period <seconds>} | {quiet-
period <seconds>} | {tx-period <seconds>} | {supp-
timeout <seconds>} | {server-timeout <seconds>}}
Interface Config
no dot1x timeout {reauth-period | quiet-period |
tx-period | supp-timeout | server-timeout}
Interface Config
parameter must be a configured user.
<user>
dot1x user <user> {<slot/port> | all}
Global Config