Download Print this page

Toshiba e-STUDIO556 Service Manual page 667

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO556:

Advertisement

Replace parts
Finisher control board
[CB50]
Staple motor abnormality
Classification
Finisher related service call
Check item
Stapler
Finisher control board
Replace parts
Stapler
Finisher control board
[CB60] Stapler shift motor abnormality
Is the stapler shift home position sensor (PI7) working normally?
NO 
YES
Is the wiring between the finisher controller PC board and the stapler shift motor (M4)
correct?
YES  Correct the wiring.
NO
Is there any mechanical problem with the stapler stand motion path?
YES  Fix the mechanism.
NO
Try replacing the staple shift motor. Is the problem corrected?
YES  END
NO
Replace the finisher controller PC board.
[CB70] Stack amount detection sensor abnormality
[Procedure 1]
Is the problem solved by turning OFF and ON the power of the equipment?
YES  END
NO
© 2011 - 2014 TOSHIBA TEC CORPORATION All rights reserved
Connector check
Harness check
Connector check
Board check
Replace the sensor.
8 - 115
Remarks
Error item
Measures
Remarks
e-STUDIO556/656/756/856/557/657/757/857
ERROR CODE AND TROUBLESHOOTING
8

Advertisement

loading