[71AC]
File save error during certificate acquisition from SCEP server
Classification
Maintenance error
Check item
Setting
[71AD]
Failed SCEP operation
Classification
Maintenance error
Check item
Setting
[71B0]
Software package file decryption failure
Classification
Maintenance error
Check item
Setting
[71D0]
Factory default setting failure
Classification
Maintenance error
Check item
Setting
[71F1]
Clone file creation failure
Classification
Maintenance error
Check item
Setting
© 2011 - 2014 TOSHIBA TEC CORPORATION All rights reserved
File save error occurred during certificate acquisition from SCEP server.
File saving failed for some reason. If the error still occurs after rebooting
the equipment, start up using the following procedure:[3] + [C] + [POWER]
-> 3. HDD formatting
-> Reinstallation of software or HDD replacement
SCEP operation is failed
Check SCEP server and the SCEP setting on the TopAccess menu as
follows:
[Administration] > [Security] > [Certificate Management] > SCEP
(Automatic)
Software package file decryption failed.
Software package file may have a problem or may be corrupted. Check the
software package file and then reattempt the installation.
Factory default setting failed.
Restart the equipment and then retry.
The creation of a clone file failed.
Check if there is enough capacity in the HDD and the USB media and then
retry the creation.
8 - 213