e-STUDIO556/656/756/856
Item
Subitem
Low-speed pre-
Pressure roller
running starting
temperature during
ready status
Low-speed pre-
Pressure roller
running stopping
temperature during
ready status
Low-speed pre-
Pressure roller
running starting
temperature during
ready status
Low-speed pre-
Pressure roller
running stopping
temperature during
ready status
Switching printing
speed
Switching printing
speed
Switching printing
speed
Switching printing
speed
Sub-
Default
Code
Details
code
value
2131
Option not installed
Refer to
(When setting 08-
contents
2130 is enabled)
2132
Option not installed
5
(When setting 08-
2130 is enabled)
2136
Option installed
10
(When setting 08-
2130 is enabled)
2137
Option installed
5
(When setting 08-
2130 is enabled)
2147
High fusing
0
mode(When thick
paper 2 is used)
2242
Plain paper
0
2243
Thick paper 1
0
2244
Thick paper 2
0
2245
Thick paper 3
0
2260
Number of sheets to
8
start reeling cleaning
web
2267
Display of remaining
0
portion of cleaning
web
5
Acceptable
RAM
Contents
value
0~16
M
0: 50°C 1: 55°C 2: 60°C 3: 65°C 4: 70°C 5: 75°C 6:
80°C 7: 85°C 8: 90°C 9: 95°C 10: 100°C 11: 105°C
12: 110°C 13: 115°C 14: 120°C 15: 125°C 16: 130°C
<Default value>
e-STUDIO556/656:
JPC: 6
Others: 10
e-STUDIO756/856: 10
0~9
M
0: +5°C 1: +10°C 2: +15°C 3: +20°C 4: +25°C 5:
+30°C 6: +35°C 7: +40°C 8: +45°C 9: +50°C
0~16
M
0: 50°C 1: 55°C 2: 60°C 3: 65°C 4: 70°C 5: 75°C 6:
80°C 7: 85°C 8: 90°C 9: 95°C 10: 100°C 11: 105°C
12: 110°C 13: 115°C 14: 120°C 15: 125°C 16: 130°C
0~9
M
0: +5°C 1: +10°C 2: +15°C 3: +20°C 4: +25°C 5:
+30°C 6: +35°C 7: +40°C 8: +45°C 9: +50°C
0~1
M
The fusing efficiency level goes up during a continuous
printing (when Thick 3 is selected).
0: Disabled 1: Enabled
0~2
M
0: Disabled 1: Enabled only for 5 minutes after
warming-up 2: Always enabled
0~2
M
0: Disabled 1: Enabled only for 5 minutes after
warming-up 2: Always enabled
0~2
M
0: Disabled 1: Enabled only for 5 minutes after
warming-up 2: Always enabled
0~2
M
0: Disabled 1: Enabled only for 5 minutes after
warming-up 2: Always enabled
0~255
M
The equipment starts reeling the cleaning web every
time the specified number of sheets have been printed.
(= Setting value X 1 sheet)
0~1
M
0: Displayed 1: Not displayed