4.13.11 Exit guide / Exit/reverse guide / Reading end guide
(1)
Take off the platen sheet unit.
( P.4-139 "4.13.8 Platen sheet unit")
(2)
Remove the RADF exit tray.
( P.4-140 "4.13.9 RADF exit tray")
(3)
Take off the original exit motor.
( P.4-163 "4.13.31 Original exit motor
(MR4)")
(4)
Take off the original reverse motor.
( P.4-163 "4.13.30 Original reverse motor
(MR3)")
(5)
Remove 1 clip, 1 pulley, 1 timing belt and 1
pin.
(6)
Remove 1 core [1] and disconnect 1
connector [2]. Remove 1 clip [3] and take off
the rear side guide bushing [4].
Note:
Only e-STUDIO657/857 has a core.
(7)
Remove 1 screw and take off the leaf spring.
e-STUDIO556/656/756/856/557/657/757/857
DISASSEMBLY AND REPLACEMENT
Timing belt
Pin
[1]
© 2011 - 2014 TOSHIBA TEC CORPORATION All rights reserved
4 - 142
Pulley
Clip
Fig. 4-397
[4]
[3]
[2]
Fig. 4-398
Fig. 4-399

Advertisement